Fig. 8.10: Compressor and compressed air receiver |

VR = Volume of compressed air receiver [m³]
= FAD of all compressors [m³/min]
LB = Required FAD [m³/min]
Al = Allowed motor cycle rate [1/h]
pmax = Cut-out pressure of compressor [barü]
pmin = Cut-in pressure of compressor [barü]
The volume of the compressed air receiver can also be defined according to the BOGE recommendation, compressor FAD to volume of compressed air receiver VR = /3.
|