5.2.6. Quantity of condensate on a humid Summer day



The quality of compressed air must always remain the same if the surrounding conditions are unchanged. i.e., the pressure dew point of the compressed air must be 3°C even on a humid Summer day with an air temperature of 40° C and 90 % atmospheric humidity.
    FAD 1 = 2720 m³/h
    Inlet pressure p1 = 1 barabs
    Inlet temperature T1 = 40°C
    Relative humidity j1 = 90 %
    Pressure dew point T3 = 2°C

Under these conditions the quality of compressed air remains constant but the quantity of condensate is much higher.

    Condensate quantity qC = 122,6 l/h

With 3-shift operation working at 100 % efficiency the compressor is running 24 hrs. per day. This means, with the basic assumptions unchanged:

    Condensate quantity qCD = 2943,3 l/D

The following quantity of condensate will then occur in one year:
    Condensate quantity qCY = 107135 l/Y