7.2.5. FAD Required L B
When calculating the FAD required
L
B
, allowances of 5 % for losses, 10 % for reserves and a 15 % margin for error are added to the calculated total consumption value
.
= 1565 l/min
v = 5 %
r = 10 %
e = 15 %
The FAD quantity
L
B
, required to give consumer devices an adequate supply of compressed air is approx. 2035 l/min. This value is the basis for determining the size of the compressor and the main pipeline.